Synertech · Joint modules

Synertech TK-P10285-18 planetary joint module

The mid-torque workhorse of the TK-P range: 48 N·m rated and 206 N·m of peak in 1.56 kg, with an 8 mm through-bore and — the reason this line exists — a holding brake as a catalogue option. Elbow, knee pitch and shoulder axes that must hold on power loss land here.

Full specification

ParameterValue
Frame / sizeΦ102 × 85 mm
Ratio18:1
Rated torque48 N·m
Peak torque206 N·m
Rated speed133.5 rpm output
Weight1.56 kg
Backlash12 arcmin
Axial / radial load10.6 / 4.68 kN
Allowable bending moment174.8 N·m
Rated power730 W
Bore8 mm hollow
Supply48 V ±10%
CommsCAN-FD only
Encoder19 or 20-bit
Holding brakeSelectable (B/N in the part number); brake-build dimensions confirmed at quotation
Torque sensorNot available on this line
Ambient−10 to 50 °C (no IP rating published)

Figures verified November 2026 — confirm the exact variant against the datasheet issued with your order.

Synertech TK-P10285-18 planetary joint module

When this is the right choice

  • Brake + hollow bore in one frame. Vertical elbow and knee axes get the holding brake and a through-bore harness in the same module — a combination the Motorevo PA line only offers by special order on one model.
  • 206 N·m peak absorbs the start-stop and landing loads of a knee.
  • 19/20-bit encoder — finer than the 14-bit standard on most planetary joints.

When it is the wrong choice

  • CAN-FD only. EtherCAT controllers need the harmonic lines (TCHL, PHU).
  • No torque sensor. Force control needs a harmonic RBV3 / PHU module.
  • 12 arcmin backlash — acceptable for legs and lifts, not for a precision wrist.

Alternatives at a similar level

Quote this model

Model, quantity and destination is enough to start — we come back with price, availability and the datasheet.

Quoting for TK-P10285-18

One business day reply. Prefer email? [email protected].

Need the STEP model, the datasheet or the CAN / EtherCAT protocol document? Ask in the message — the drawing set and datasheet come back with the quotation.

TK-P10285-18 FAQ

Can the TK-P10285 hold a vertical load on power loss?

With the brake option, yes — that is exactly what the B/N code position is for. Size the brake against the gravity torque your axis must hold, not against the 48 N·m rated figure, and tell us the load: the brake-build drawing comes back with the quotation.

How does it compare with the Motorevo PA100-20-18?

The PA carries more rated torque (60 vs 48 N·m) at similar mass. The TK-P answers with the catalogue brake option, the 8 mm bore and a 19/20-bit encoder. If the axis needs a brake, this is the shorter path.

Is there a torque sensor version?

No. Nothing in the TK-P line measures torque. For force control use Crabnova RBV3 or EYOU PHU harmonic modules.

Back to Synertech (SYNERTECH) · all joint modules · need a model that is not listed?