Supported motor types
motor_type_str must match a key in MODEL_NAMES in src/lerobot/motors/damiao/tables.py. The limits below come from MOTOR_LIMIT_PARAMS in the same file.
| motor_type_str | PMAX (rad) | VMAX (rad/s) | TMAX (N·m) |
|---|---|---|---|
dm3507 | 12.5 | 30 | 10 |
dm4310 | 12.5 | 30 | 10 |
dm4310_48v | 12.5 | 50 | 10 |
dm4340 | 12.5 | 8 | 28 |
dm4340_48v | 12.5 | 10 | 28 |
dm6006 | 12.5 | 45 | 20 |
dm8006 | 12.5 | 45 | 40 |
dm8009 | 12.5 | 45 | 54 |
dm10010l | 12.5 | 25 | 200 |
dm10010 | 12.5 | 20 | 200 |
dmh3510 | 12.5 | 280 | 1 |
dmh6215 | 12.5 | 45 | 10 |
dmg6220 | 12.5 | 45 | 10 |
These are firmware command-scaling limits, not datasheet ratings. A 48 V suffix marks a different speed limit entry for the same motor family, not a different mechanical part.
Encoder and CAN settings
- All 13 models use a 65536-count encoder (MODEL_RESOLUTION).
- Default CAN bitrate is 1 Mbps; supported rates run from 125 kbps to 5 Mbps.
- OpenArms default IDs follow send ID 0x0N / receive ID 0x1N, where N is the joint number.
These are motors, not joint modules
LeRobot’s DAMIAO driver addresses bare CAN motors in MIT mode. The DM-J and DM-JH joint modules are a different product class: a gearbox, housing, output bearing and encoder are integrated around the motor, so their torque, backlash and frame data come from a different table. Do not use a TMAX value above to size a joint module axis, and do not feed a joint-module rated torque into LeRobot’s scaling. For the selection-side view see rated versus peak torque and the planetary joint modules page.
Need the module datasheet?
We publish catalogue figures for the standard build and confirm the exact winding, ratio and options against the datasheet issued with your quotation.
- What you need (model or description), and quantity
- Destination country
- Target lead time
LeRobot DAMIAO configuration FAQ
Why does LeRobot reject my motor_type string?
It has to match a key in MODEL_NAMES in src/lerobot/motors/damiao/tables.py exactly. Keys are lowercase and use an underscore for the 48 V variants: dm4310_48v is valid, DM4310 and dm4310-48v are not. The 13 valid values are listed in the table above.
Can I use PMAX, VMAX and TMAX as datasheet ratings?
No. They are firmware limits used by the driver to scale commands and decode state, not mechanical ratings. Size an axis on rated torque from the datasheet and reserve peak figures for transients — see rated versus peak torque in the glossary.
Are LeRobot DAMIAO motors the same as DAMIAO joint modules?
No. The LeRobot DAMIAO driver talks to bare CAN motors running MIT mode. DM-J and DM-JH joint modules add a gearbox, housing, output bearing and integrated encoder, and expose different limits entirely. Do not carry a value from one across to the other.
Back to developer docs · DAMIAO joint modules · CAN vs EtherCAT